NEUROBOT MOTOR BCI
BCI Motor Imagery Neural Decoder ยท 3D Cybernetic Limbs
CHECKING...
โšก Real-Time Decoded Neural Intent
--
Confidence: -- ยท Ground Truth: -- ยท t = 0.000s
--
Full Humanoid Cybernetic Robot ยท Three.js Laboratory Bay REST IDLE
FULL HUMANOID CHASSIS: TORSO REACTOR ยท 5 ARTICULATED DIGITS (MANUAL TEST; PAPER FINGER TASKS USE THUMB, INDEX, PINKY)
REST
๐Ÿ“ˆ EEG Signal Window (6 of 64 channels, common average referenced, 4โ€“40 Hz, stored at 40 Hz)
Source: loading...
0 / 0
๐Ÿ“Š Class Probabilities
SOFTMAX
โš™๏ธ Active Motor Task
Movement type:
Need to decode custom EEG data?
๐Ÿงช Custom EEG Ingestion & Neural Decoding Studio
SUPPORT FOR EDF, EDF+, CSV, TSV & JSON
๐Ÿ“ฅ
Click or Drag & Drop EEG Files Here
Upload clinical or BCI headset EEG recordings. The pipeline will automatically resample, apply Common Average Referencing (CAR), 4-40Hz bandpass filter, and decode with the trained NeuroBot model.
.EDF / .EDF+ .CSV (64-Ch) .TSV .JSON Log
Instant Testing Presets & Sample Files
โšก Synthetic Left/Right Trial
Generates 15s of realistic EEG with simulated 10Hz Mu rhythm desynchronization.
โšก Synthetic Fists/Feet Trial
Simulates alternating Rest, Both Fists, and Both Feet sensorimotor bursts.
๐Ÿ“ฅ Download Sample CSV
Downloads a 64-channel 160Hz formatted CSV ready to test upload.
๐Ÿ“ Bundled Replay Log
Loads the stored replay log of the selected task into the decoding pipeline.
Pipeline Parameters
Decoding Pipeline Status
โœ“
1. Input Ingestion
Ready to receive file or synthetic stream
2
2. Channel Standardization
Standard 10-20 montage alignment (64 channels)
3
3. CAR & 4-40Hz Bandpass Filter
Zero-phase 4โ€“40 Hz FIR filter (same as in training)
4
4. Model inference
Trained model, 1 s windows every 125 ms
๐Ÿง  10-20 International Electrode Cap & Channel Telemetry
64-CHANNEL SENSORIMOTOR TOPOGRAPHY
Click an electrode on the 10-20 montage. Only the channels stored in the replay (C3, CZ, C4, FC3, FC4, CPZ) have a trace and band power.
CH: C3 (LEFT MOTOR CORTEX)
Primary sensorimotor area corresponding to right hand/fist motor imagery desynchronization.
RMS (z-score): --
Peak-to-peak (z-score): --
SNR: n/a
Status: --
Frequency band power (not computed: the stored traces are decimated 4ร—, which aliases the 20โ€“40 Hz part)
Delta (outside the 4 โ€“ 40 Hz filter)
n/a
Theta (4 โ€“ 8 Hz)
n/a
Mu (8 โ€“ 13 Hz)
n/a
Beta (13 โ€“ 30 Hz)
n/a
Low gamma (30 โ€“ 40 Hz)
n/a
Channel Signal Oscilloscope
๐Ÿ“Š Session Performance Metrics & Confusion Matrix
PER-WINDOW EVALUATION OF THE LOADED LOG
--
Overall Accuracy (3-Class)
--
Windows Decoded
--
Mean Softmax Confidence
125 ms
Inference Cadence (Stride)
Confusion Matrix Heatmap
Session Confidence Timeline Over Time